Pump type
Energy efficiency index (EEI) of
the pump
Technical data – Domestic hot water
Domestic hot water cylinder ma-
terial
Length of the magnesium protec-
tion anode
Maximum operating pressure
Max. cylinder temperature due to
the heat pump
Max. cylinder temperature due to
back-up heater
Technical data – Refrigerant circuit
Material, refrigerant pipe
Connection technology, refriger-
ant pipe
Outer diameter, hot gas pipe
Outer diameter, liquid pipe
Minimum wall thickness, hot gas
pipe
Minimum wall thickness, liquid
pipe
Refrigerant, type
Refrigerant, Global Warming Po-
tential (GWP)
Technical data – Electrics
Built-in fuse (slow-blow), on the
control PCB
Min. electrical power consumption
of the heating pump
Max. electrical power consump-
tion of the heating pump
Note
All specific and required information for the split installation and components of the outdoor unit are included in
the corresponding installation instructions for the outdoor unit, which is used in combination with the current indoor
unit.
268
HA 6-8/8.2 STB
High-efficiency pump
≤ 0.2
HA 6-8/8.2 STB
Steel, enamelled
897 mm
1.0 MPa
(10.0 bar)
55 ℃
70 ℃
HA 6-8/8.2 STB
Copper
Flare connection
1/2" (12.7 mm)
1/4" (6.35 mm)
0.8 mm
0.8 mm
R32
675
HA 6-8/8.2 STB
4 A
2 W
75 W