4.6.4
Temporarily switching off heating mode
(absence)
Validity: Product with control module
1.
Call up MENU | CONTROL | Absence.
2.
Set a start time and an end time.
◁
The frost protection function is active.
4.6.5
Permanently switching off heating mode
(summer mode)
Condition: No system control connected
▶
From the basic display, press
seconds.
◁
Heating mode is switched off.
◁
The symbol for heating mode is shown as deactivated
in the display.
Condition: System control connected
▶
Observe the instructions for the system control.
4.7
Cooling mode
In cooling mode, the rooms are cooled in accordance with
your settings.
4.7.1
Activating permanent cooling
Validity: Product without control module
1.
Call up MENU | CONTROL | Permanent cooling.
2.
Activate permanent cooling.
4.7.2
Activating cooling for several days
Validity: Product with control module
1.
Call up MENU | CONTROL | Cooling for several
days.
2.
Enter the start and end day.
4.8
DHW mode
In domestic hot water mode, the potable water is heated to
the required domestic hot water temperature.
4.8.1
Setting the domestic hot water temperature
Validity: Product without control module
▶
From the basic display, press
▶
Set the required domestic hot water temperature.
Validity: Product with control module
▶
Call up MENU | CONTROL | DHW | Mode:.
▶
Activate the Manual mode.
▶
Call up Desired temperature:.
▶
Set the required domestic hot water temperature.
8000017440_FT Operating instructions
▶
4.8.2
for at least three
4.8.3
▶
▶
4.9
You can use this function to display the energy consumption
values for various time periods.
▶
4.10
4.11
.
Condition: System control connected
Set the domestic hot water temperature on the system
control. Observe the instructions for the system control.
Setting the time-controlled domestic hot
water temperature
Validity: Product with control module
1.
Call up MENU | CONTROL | DHW | Mode:.
2.
Activate the Time-contr. mode.
3.
Call up Desired temperature:.
4.
Set the required domestic hot water temperature.
5.
Call up the Domestic hot water weekly planner and
program the required time periods for each day of the
week.
6.
If a circulation pump is installed, call up Circulation
weekly planner and programme the desired time
periods for each day of the week.
Switching off the domestic hot water mode
Condition: No system control connected
Starting from the basic display, press
seconds.
◁
The domestic hot water mode is switched off.
Condition: System control connected
Observe the instructions for the system control.
Displaying the energy data
Call up MENU | INFORMATION | Energy data.
Activating ventilation boost
Validity: Product with control module
You can use this function to switch off heating mode for 30
minutes.
▶
Call up MENU | CONTROL | Ventilation boost.
Switching off the installation (prolonged
absence)
Validity: Product with control module
1.
Call up MENU | CONTROL | Installation off.
2.
Deactivate the installation.
◁
The installation is switched off.
◁
Frost protection and, if available, ventilation re-
main activated at the lowest level.
for at least five