OPERATION
The oven continues working and only probe 1 is used to measure the
temperature. The control temperature is also automatically raised by
40°C.
This variation in the temperature corrects the only value read in the
coldest part of the oven and simulates an approximate value to the
effective value which was previously set by supplying the average of
values between the hottest and coldest points. This allows the oven to be
used even when a probe breaks.
5.6.3 "OVER"
If the temperature measured by probe 1 exceeds 350°C and probe 2
exceeds 450°C at the same time, the temperature value on the display is
replaced by the flashing word "OVER" and the alarm sounds
intermittently.
Switch off the alarm by pressing the key
.
necessary to call in specialists to restore functionality
5.6.4 "BELT"
When the mesh motor is broken or sends wrong signals to the circuit board,
the word "BELT" ("RETE") flashes on the display and the alarm sounds
intermittently. This means that the cooking time does not correspond to the
set value and that specialized personnel are required to reset the functions
of the oven.
5.6.5 "BATTERY"
When the buffer battery installed on the main electronic board is exhausted,
an alarm is activated on the display together with the flashing writing
"Battery" and the acoustic signal plays in intermittent way. To replace the
battery see paragraph 8.3.