Pump Setting Menu for TV2k-G, TV3k-T
Figure 28
This menu contains all the parameters that have a direct effect on
driving of the pump.
Turbo-V Remote Panel User Manual / 87-900-987-01
Flow - 2/6
HIGH SPEED: Sets (in Hz) the speed of rotation of the pump
when the low-speed function is not active.
LOW SPEED: Sets (in Hz) the speed of rotation of the pump
when the low-speed function is active.
SOFT START: enables (YES) or disables (NO) the soft start
function. This parameter is visible only if the controller is
configured in FRONT mode.
VENT VALVE MODE: makes it possible to select driving of the
vent valve
Technical Information
(E)
17
Programming
281/304