Where:
Black rectangles as shown below may be displayed at any time in the
first and last box of the bottom line of the display (opposite the LS /
AG / R1 / R2 captions). The meaning of these rectangles is as
follows:
Figure 23
Turbo-V Remote Panel User Manual / 87-900-987-01
XXXXXX: indicates the status of the pump
XXXHz: is the current frequency of rotation of the pump. This
value can be modified by the user according to needs, proceeding
as described in the "PROGRAMMING" paragraph. The unit of
measurement (HZ / Krpm, default = Hz) is selected by the user
from the INPUT/OUTPUT->SPEED menu.
The operating mode of the controller is shown at the bottom in
the center. This may be:
FRONT: front mode (the controller accepts START/STOP and
LOW SPEED commands from the front panel)
REMOTE: remote mode (the controller accepts START/STOP and
LOW SPEED commands via the rear connector)
RS232: the controller accepts commands from the serial port
according to the RS232 standard.
LS → the controller is at LOW SPEED
AG → the Gauge is connected to the controller
R1 → relay (set point ) R1 is active
R2 → relay (set point ) R2 is active
LS
AG
Technical Information
How to use by Front Panel
(E)
17
R1
R2
267/304