E E n n v v i i r r o o n n m m e e n n t t a a l l c c o o n n d d i i t t i i o o n n s s
Temperature
Relative humidity
Atmospheric pressure
Specifications listed are approximate and may vary slightly from product to product or by power supply fluctuations.
Stryker reserves the right to change specifications without notice.
S S t t a a n n d d a a r r d d s s a a p p p p l l i i e e d d
IEC 60601-1:2012
IEC 60601-1-2:2014
IEC 60601-2-52:2009 + A1:2015
IEC 60601-2-54:2009 + A1:2015*
*Only applicable when the product is equipped with the
radiolucent backrest option
W W A A R R N N I I N N G G - - Only use the input voltage and frequency as rated on the product.
C C A A U U T T I I O O N N
• To minimize the risk of any electromagnetic interference, the product design follows the standard IEC 60601-1-2. To
avoid problems, use the bed in accordance with the EMC/EMI requirements in the EMC section of this operations
manual.
• Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should
be used no closer than 30 cm (12 in.) to any part of the SV2, including cables specified by the manufacturer. Otherwise,
degradation of the performance of this equipment could result.
• Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper
operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are
operating normally.
• Use of accessories, transducers, and cables other than those specified or provided by the manufacturer of this
equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this
equipment and result in improper operation.
EN
10
O O p p e e r r a a t t i i o o n n
90%
20%
1060 hPa
800 hPa
Medical electrical equipment - Part 1: General requirements for
basic safety and essential performance
Medical electrical equipment - Part 1-2: General requirements
for basic safety and essential performance - Collateral
standard: Electromagnetic compatibility - Requirements and
tests
Medical electrical equipment - Part 2-52: Particular
requirements for the basic safety and essential performance of
medical beds
Medical electrical equipment - Part 2-54: Particular
requirements for the basic safety and essential performance of
X-ray equipment for radiography and radioscopy
S S t t o o r r a a g g e e a a n n d d t t r r a a n n s s p p o o r r t t a a t t i i o o n n
(50 °C)
(-10 °C)
90%
20%
1060 hPa
800 hPa
KK-7500 REV 08