Install the panel-mounted version of the 8025 into an electrical cabinet with
IP54 minimum protection rating to ensure a degree of pollution 2 inside the
device.
Use the supplied drilling jig to cut away the necessary opening in the panel. Respect the
dimensions indicated (see Fig. 4 ).
Place the gasket on the 4 screws of the cover. Use the 4 supplied M4*25 screws if the
panel door is too thick.
Place the cover + gasket set on the cut-away with the electronic board facing the inside
of the panel.
Insert the 4 washers onto the 4 screws and fit the device to the panel using the 4 nuts.
Connect according to instructions described at chapter
Nut
Gasket
Fig. 11 : Installation of a panel-mounted version of the 8025
4.1.4.

Install a wall-mounted version of the 8025

The bottom enclosure of the transmitter in a wall-mounted version has 4 fixing holes.
Remove the white blanking stripes, then open the housing cover to access the fixing
holes [1].