Inserting The Cable Clips (Versions Without En 175301-803 Male Fixed Connector); Configure The Flow Sensor Selector - Burkert 8025 Manuel Utilisateur

Transmetteur de débit
Masquer les pouces Voir aussi pour 8025:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and electrical wiring
4.2.3.
Inserting the cable clips (versions without
EN 175301-803 male fixed connector)
Fig. 19 :
Using the cable clips
4.2.4.

Configure the FLOW SENSOR selector

Before wiring the device, configure the selector on the electronic board.
Transmitter version
All
All
4.2.5.
Electrical wiring of a 8025 compact and a 8035,
12-36 VDC, without relays, with cable glands
Seal the unused cable gland using the stopper supplied to make sure the
device is tight.
Unscrew the cable gland nut, insert the obstructor and screw the nut back onto
the cable gland.
Only configure the selectors by unpowered device.
Lift the transparent lid after having unfastened the screw.
Unscrew the 4 screws then remove the cover from the device.
Insert the cable clips (see chap.
Pass the cables through the cable glands
Connect terminals according to pin assignment described below.
Before wiring the device, insert the supplied cable clips into
the cuts of the electronic board and, if fitted into the cut of
the 115/230 VAC-power supply board.
Output signal of the remote
sensor
Pulse, NPN (hall)
Sinus (coil)
4.2.3 ).
E-23-
Flow transmitter 8025/8035
Position of the FLOW
SENSOR selector
NPN
COIL