Adjustment and functions
The following table gives the response time (10% to 90%) :
Filtre
0
1
2
3
4
FILTER
TOTAL
If you do not want to adjust another parameter, go to the "END" parameter of the Set-
tings mode and press the "ENTER" key to save the settings and go back to the Read
mode.
5.3.8.

Totalizer

This function makes it possible to simultaneously reset both totalizers. The reset is only
effective after the ENTER key has been pressed when the "END" function of the Settings
mode is displayed.
TOTAL
END
If you do not want to adjust another parameter, press the "ENTER" key when the "END"
parameter of the Settings mode is displayed to save the settings and go back to the
Read mode.
Response time
0,15 s
0,7 s
1,4 s
2,5 s
3,5 s
FILTER 0
FILTER 9
RES NO
RES YES
E-45-
Flow transmitter 8025/8035
Filtre
5
6
7
8
9
Response time
6 s
10 s
19 s
33 s
50 s