Burkert 8025 Manuel Utilisateur page 10

Transmetteur de débit
Masquer les pouces Voir aussi pour 8025:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical data
Type of fluid
Fluid temperature (compact
version)
with fitting in PVC
with fitting in PP
with fitting in PVDF, stainless
steel or brass
Fluid pressure
8025 compact
8035 with S030 fitting in
plastic
8035 with S030 fitting in
metal
Flow rate measurement
Flow rate range
-
sensor with pulse output
(Hall)
-
Sensor with a sinus output
(coil)
Accuracy of the flow rate
measurement
1)
(see Fig. 1 )
-
with Teach-in
-
with standard K factor
1)
Linearity
Repeatability
1)
1)
In the following reference conditions,i.e. fluid = water, water and ambient temperatures = 20 °C, min. upwards and
downwards distances respected, appropriate pipe dimensions.
liquid
viscosity: max. 300 cSt
rate of solid particles: max. 1%
The fluid temperature may be restricted by the fluid
pressure (see Fig. 8 ).
0 to +50 °C
0 to +80 °C
-15 to +80 °C
The fluid pressure may be restricted by the fluid tempe-
rature and the material of the fitting used (see Fig. 8 ).
PN10
PN10
PN16 (PN40 on request)
-
0.3 m/s to 10 m/s
-
0.5 m/s to 10 m/s
±
-
0.5 % of the full scale (at 10 m/s)
±(
-
0.5 % of the full scale + 2.5 % of the measured
value)
±0.5 % of the full scale (at 10 m/s)
0.4 % of the measured value
E-8-
Flow transmitter 8025/8035

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

8035