Technical data
Type of fluid
Fluid temperature (compact
version)
•
with fitting in PVC
•
with fitting in PP
•
with fitting in PVDF, stainless
steel or brass
Fluid pressure
•
8025 compact
•
8035 with S030 fitting in
plastic
•
8035 with S030 fitting in
metal
Flow rate measurement
•
Flow rate range
-
sensor with pulse output
(Hall)
-
Sensor with a sinus output
(coil)
•
Accuracy of the flow rate
measurement
1)
(see Fig. 1 )
-
with Teach-in
-
with standard K factor
1)
•
Linearity
•
Repeatability
1)
1)
In the following reference conditions,i.e. fluid = water, water and ambient temperatures = 20 °C, min. upwards and
downwards distances respected, appropriate pipe dimensions.
•
liquid
•
viscosity: max. 300 cSt
•
rate of solid particles: max. 1%
The fluid temperature may be restricted by the fluid
pressure (see Fig. 8 ).
•
0 to +50 °C
•
0 to +80 °C
•
-15 to +80 °C
The fluid pressure may be restricted by the fluid tempe-
rature and the material of the fitting used (see Fig. 8 ).
•
PN10
•
PN10
•
PN16 (PN40 on request)
-
0.3 m/s to 10 m/s
-
0.5 m/s to 10 m/s
±
-
0.5 % of the full scale (at 10 m/s)
±(
-
0.5 % of the full scale + 2.5 % of the measured
value)
•
±0.5 % of the full scale (at 10 m/s)
≤
•
0.4 % of the measured value
E-8-