Clearing The Settings; Unlocking/Locking The Motors - SOMFY SGS LINE Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6
Troubleshooting guide

6.3 Clearing the settings

When should I clear the settings?
• A er programming the gate leaf travel, if you change the opening position stop or if you modify the motor wiring.
• If the gate opens at random due to normal wear of the gate.
1
>2s
Press the
button on the
control electronics for 2
seconds.
The indicator light
comes
on.
5
To clear the settings*
Keep button 2 of the remote control depressed until the
"RESET" indicator light comes on.

6.4 Unlocking/locking the motors

When unlocking the motors, the gate may be manoeuvred manually if there is an electrical fault.
1
Unlocking the motors
Unclip the unlocking mechanism, then remove the cylinder
from the gate leaf mounting bracket.
30
EN - SGS LINE installation and operating guide - SOMFY
2
Place the memorised remote
control on the target.
6
3
Keep button 1 of the remote
control depressed until the
indicator light flashes.
To clear the settings* and the memorised remote
5
controls/control points
Keep button 2 of the remote control depressed until all the indicator
lights come on.
The indicator light
flashes twice (see "Gate travel auto-
programming" page 20).
*Gate travel, deactivation of the settings, etc.
2
Locking the motors
Fit the cylinder. Clip the unlocking mechanism on the catch to
secure it.
4
Press button 1 on the remote
control once.
The "RESET" indicator light
flashes.

Publicité

Table des Matières
loading

Table des Matières