P40
Coupling speed when closing
P41
Coupling speed when opening
Values
1: slowest speed
to
4: fastest speed
Default value: 2
Warning
Comments
If parameters P40 or P41 are changed, the
installer must check that the obstacle detection
system complies with appendix A of standard EN
12 453. If necessary, install a safety edge and
check that compliance is obtained.
Failure to follow this instruction may result in
serious injury, e.g. due to crushing by the gate.

8. PROGRAMMING THE REMOTE CONTROLS

8.1. Memorising 2- or 4-button remote controls via
the programming interface
Up to 40 command channels can be memorised and assigned as desired
among the commands listed below. If the memory is full, the screen dis-
plays "FuL".
If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared. The screen displays "dEL".
8.1.1. Complete opening control - Fig. 28
8.1.2. PEDESTRIAN opening control - Fig. 29
8.1.3. LIGHTING control - Fig. 30
8.1.4. AUXILIARY OUTPUT control (P15 = 4, 5 or 6) - Fig.
31
8.2. Programming 3-button remote controls via the
programming interface - Fig. 32
1) Press and hold the "PROG" button (2 s).
The screen displays "F0".
Pressing "PROG" again allows the next function to be memorised.
2) Press "PROG" at the rear of the 3-button remote control to memorise
the function.
The screen displays "Add".
Button functions on a 3-button remote control
F0
Complete opening
F1
Complete opening
F2
Lighting ON
F3
Aux. output ON
11
my
Stop
Complete closing
Complete closing
If gate is closed
pedestrian opening
Otherwise
stop
Lighting OFF
Aux. output OFF
8.3. Memorising remote controls with no access to
the programming interface
Attention
This operation must be carried out close to the motor.
A = "source" remote control already memorised
B = "target" remote control to be memorised
Copying the function from a Keygo RTS remote control button to a
button on a new 2- or 4-button remote control - Fig. 33
Copying the function from a 3-button remote control to a new
3-button remote control - Fig. 34
9. CLEARING THE REMOTE CONTROLS
AND ALL SETTINGS

9.1. Clearing memorised remote controls - Fig. 35

Press the "PROG" button for 7 s.
Causes all programmed remote controls to be cleared.

9.2. Clearing all settings - Fig. 36

Press and hold the "SET" button for 7 s.
Clears the auto-programming and resets the default values for all param-
eters.
10. LOCKING THE PROGRAMMING BUT
TONS FIG. 37
Warning
The keypad must be locked to ensure the safety of the users.
Failure to follow this instruction may result in serious injury, e.g.
due to crushing by the gate.
Locks the programming (end limits, auto-programming, parameter set-
tings).
When the programming buttons are locked, a dot appears a er the 1st
digit.
Pressing the "SET", "+", "-" buttons:
• - the "SET" button must be pressed first.
• the "+" and "-" buttons must be pressed simultaneously within 2
seconds.
To access the programming again, repeat the same procedure.