4

ADVANCED PARAMETER SETTINGS

4.1 Pedestrian opening

Pedestrian opening operation

Pedestrian opening(motor M1) by pressing the activated button.
Stop when moving by pressing the activated button again.
Close by pressing the activated button again.

Activating the pedestrian opening

Button 1 on 2- or 4-button remote controls cannot be programmed to control pedestrian opening.
See "Description of the remote controls" page 27 for more information.
1
Press the
button on the control
electronics for 2 seconds.
The
indicator light comes on.
Move away from the control electronics when testing pedestrian opening.
Deactivating pedestrian opening
Repeat the "Activate pedestrian opening" procedure using the button for which the pedestrian opening must be deactivated. The indicator light
comes on then goes out. The pedestrian opening is deactivated on this button.
24
EN - SGS LINE installation and operating guide - SOMFY
2
>2s
Position the remote control on the control
electronics target.
STOP
3
<0,5s
Press button 2 on the remote control.
The "RADIO" and
indicator lights come
on then go out.
Pedestrian opening is activated on this
button.