1.5 Connecting the motors

Motor M1 activates the gate leaf which:
• opens first and closes last,
• opens for pedestrian access.
1
M1 est à gauche
M1 on the le
2
Connect the motors as indicated in the table below:
Connect motor wire...
M1
M2

1.6 Connecting to the power supply

For your safety, these operations must be carried out with the power supply switched off.
Use a 3 1.5 x 1.5 mm² cable for outdoor use (at least H07RN-F type).
The cable clamp supplied must be used. For all low-voltage cables, ensure that they can withstand traction of 100 N.
Check that the conductors have not moved when this traction has been applied.
1
4 cm
Live
Neutral
On a 3 x 1.5 mm² type cable, prepare 2 x 4 cm wires (live and
neutral).
18
EN - SGS LINE installation and operating guide - SOMFY
or
OU
to terminal ...
blue
10
brown
11
blue
12
brown
13
230V power supply cable
With the gate closed, identify the gate
leaf that opens first.
Motor M1 activates this gate leaf.
M1 est à droite
M1 on the right
2
Cable clamp
• Connect live and neutral to terminals 16 and 17 (red "230 V"
label).
• Immobilise the 230 V power cable with the cable-clamp provided (r).
• Fit a terminal block on the earth wire (yellow/green) and store
it in the control unit.
Live
Neutral
230V power supply cable