2.1 Switching the installation on
The
indicator light flashes (twice).
The motorisation is switched on and awaiting auto-programming.
If the
indicator light does not come on or the number of flashes is not as expected: see "Diagnostics" page 31.
2.2 Adjusting the opening stop
Opening end stop
The opening stops are integrated into the cylinder. They delimit the travel of the gate leaf when opening.
N.B.: Your installation must be equipped with closing stops secured to the ground to mark out the travel of the gate when closing.
During this phase, pressing button 1 on the programmed remote control only causes the gate to open and stop (1st press = open, 2nd press
= stop, 3rd press = open, 4th press = stop, etc.), you can therefore set the desired opening position in several increments. it will be possible to
close the gate once the opening stops are installed.
1
2
3
4
COMMISSIONING AND STANDARD USE
STOP
STOP
• Press button 1 on the remote control.
A er a few seconds, the first gate leaf opens, slowly.
If the gate leaf does not open, check that the motors are
wired as shown on page 18.
• Press button 1 on the remote control again to stop the
gate leaf in the desired opening position.
Position the opening stop in contact with the cylinder knob
then tighten the stops using an Allen key, diameter 3 (2
screws per stop).
Perform 2 full turns of the key a er contact.
Press button 1 on the remote control.
The second gate leaf opens.
Press button 1 on the remote control again to stop the gate
leaf in the desired opening position.