Parameter Setting And Operating Options; Specific Operation; Clearing The Remote Controls And All Settings; Unlocking The Parameters Menu Fig - SOMFY HOME MOTION Dexxo Compact RTS Manuel D'installation

Masquer les pouces Voir aussi pour HOME MOTION Dexxo Compact RTS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Dexxo Compact RTS
7 - PARAMETER SETTING AND
OPERATING OPTIONS
7.1 General parameter setting diagram - Fig.24
7.2 Meaning of different parameters
Programming example: Adjusting the long slow zone (Fig. 25)
Indicator
Obstacle detection sensitivity
light A
Indicator
1
light B
2
3
: standard
4
If this parameter is changed, the installer must check that the obstacle
detection complies with appendix A of standard EN 12 453.
Failure to follow this instruction may result in serious injury, e.g. due to
crushing by the gate.
Indicator
Docking speed when closing
light A
Indicator
1
light B
2
: short slowing
Comments
If this parameter is changed, the installer must check that the obstacle
detection complies with appendix A of standard EN 12 453.
Failure to follow this instruction may result in serious injury, e.g. due to
crushing by the gate.
Indicator
Auto-programming mode
light A
Indicator
2
: waiting for auto-programming
light B
0
: self-learning is complete
Indicator
Locking the parameters menu
light A
Indicator
0
: the parameters menu is locked
light B
Indicator
light A
Indicator
1
light B
2
Memorising the remote control for operation in "Partial opening"
mode (Fig. 26)
The remote controls supplied in the kit have already been memorised.
If this procedure is carried out using a channel which has already been
Memorising a Telis type remote control or similar (Fig. 27)
Copyright © 2015 Somfy SAS. All rights reserved
WARNING
WARNING
Power supply

8 - SPECIFIC OPERATION

See the user booklet.
9 - CLEARING THE REMOTE CONTROLS
AND ALL SETTINGS
9.1 Deleting remote controls - Fig. 28
B
Causes all memorised remote controls to be cleared.
9.2 Reinitialising all settings - Fig. 29
[1].
A
[2].
B" to enter auto-programming mode. Indicator light B
[3].
engaged on the carriage and brings the door to the closed position.
[4].
B" to launch the auto-programming cycle.
-
-
10 - UNLOCKING THE PARAMETERS MENU
FIG. 30
Note: If the parameters menu is locked and no memorised remote control
[1].
[2].
to indicate that unlocking has taken place.
[3].
Once the work being carried out by the professional is complete, the
parameters menu must always be locked to ensure the safety of users.
Failure to follow this instruction may result in serious injury, e.g. due to
crushing by the gate.
11 - REFITTING THE COVER FLAP - FIG. 31
A" so that the transmission shuttle is
WARNING

Publicité

Table des Matières
loading

Table des Matières