7
TECHNICAL DATA
Power supply
Motor type
Motor output
Max. power consumed
(with area lighting)
Standby consumption
Maximum frequency of movements per day
Opening time
Automatic obstacle detection
Operating temperature
Thermal protection
Index protection rating
Integrated radio receiver
Remote controls:
- Radio frequency
- Range in field of use
- Storage quantity
Possible connections:
- Flashing light output
- Lighting output
- Accessories power supply output
- Backup battery input
- Photoelectric cells input
- Dry contact type control input
32
EN - SGS LINE installation and operating guide - SOMFY
230 V-50Hz/24 V (with solar power)
24 V
120 W
600 W
3 W (without accessories)
20 cycles per day
10 cycles per day using solar power
20 s minimum to 90°
Compliant with standard EN 12 453
-20°C to +60°C
Yes
IP 44
Yes
433.42 MHz, < 10mW
~ 30 m
16
Flashing, 24 V, 10 W maximum
500 W max. for 230 V (halogen or incandescent lights only)
24 Vdc / 15 W max
Yes
Yes
Yes (does not operate in the event of battery or solar power supply)