Photoelectric cells
Comments CAUTION! If, when P4=2 is confirmed, the P4 and
photoelectric cell indicator lights are flashing, there is a
short-circuit on the cells safety input. Review the
connection of the cells (see Photoelectric cells
[} p.20])CAUTION!
WARNING! If operating in remote control mode with
automatic closing (P0=2 or 3), connection of standard cells
with auto-test via power supply switching (P4 = 3) is
mandatory. The auto-test is run every operating cycle.
WARNING! In every other case, the operation of the cells
installed must be tested every 6 months.
Px
Door type
Values
1: Sectional
2: Side
3: Up-and-over
Comments CAUTION! If the parameter has been changed after auto-
programming, the motorisation returns to non-configured
mode. Auto-programming must be performed again.
7.3
Settings via the Set&Go tool (optional)
Additional settings are possible with the Set&Go programming tool:
• Closing time-delay adjustment in sequential + closing time-delay
modes (P0=2 or P0=3)
• Independent opening and closing setting speeds
• Closing slowing speed setting
• Setting the independent opening and closing slowing area length
• Pedestrian opening position adjustment.
8
PROGRAMMING THE REMOTE
CONTROLS
8.1

Memorising the 4-button remote controls

NOTICE
If this procedure is carried out using a button which has already been mem-
orised, the button will be cleared.
See also
2 Memorising the remote controls for operation in "complete opening"
mode [} p.19]
8.1.1
Via the programming interface
1] Press the "PROG" button (≈2 s) until the integrated lighting and the
"PROG" indicator light are lit constantly.
NOTICE
Pressing "PROG" again allows you to memorise the next function (partial
opening, Aux 230 V output control, integrated lighting control)
2] Briefly press the outer left and right buttons on the remote control
simultaneously.
3] Briefly press the button selected to control the function (complete
opening, partial opening, Aux 230 V output control, integrated lighting
control).
Complete opening control
Memorising the remote controls for operation in "complete opening" mode
[} p.19]
Partial opening control
> > > Illustration 34
Aux 230 V output control
> > > Illustration 35
Integrated lighting control
> > > Illustration 36
8.1.2
By copying a previously memorised remote control
> > > Illustration 37
22
This operation is used to copy the programming from a previously memor-
ised remote control button.
1] Press the outer left and right buttons on the previously memorised re-
mote control simultaneously until the indicator light flashes.
2] Press and hold the button to be copied on the previously memorised
remote control for 2 seconds.
3] Briefly press the outer left and right buttons on the new remote con-
trol simultaneously.
4] Briefly press the selected button to actuate the motorisation on the
new remote control.
Key:
Remote control "A" = "source" remote control already memorised
Remote control "B" = "target" remote control to be memorised
8.2

Memorising the 3-button remote controls

8.2.1
Via the programming interface
> > > Illustration 38
1] Press the "PROG" button (≈2 s) until the integrated lighting and the
"PROG" indicator light are lit constantly.
NOTICE
Pressing "PROG" again allows you to memorise the next function (partial
opening, Aux 230 V output control, integrated lighting control).
2] Press "PROG" at the back of the remote control.
ð The integrated lighting and "PROG" indicator light flash for 5 s.
8.2.2
By copying a previously memorised remote control
> > > Illustration 39
Key:
Remote control "A" = "source" remote control already memorised
Remote control "B" = "target" remote control to be memorised
8.2.3
Function of the 3-button remote control buttons
Function
Up button
Complete
Complete
opening
opening
Partial opening
Complete
opening
Aux 230 V
Aux. output ON
Integrated
ON
lighting
9
CLEARING THE REMOTE CONTROLS
AND ALL SETTINGS
9.1

Clearing the memorised remote controls

> > > Illustration 40
Press the "PROG" button (≈7 s) until the "PROG" indicator light flashes.
All memorised remote controls will be cleared.
9.2

Deleting the settings

> > > Illustration 41
Press the "SET" button (≈ 7 s) until the "SET" indicator light flashes quickly.
This causes all settings to be reset to the default values.
10 LOCKING THE PROGRAMMING
BUTTONS
> > > Illustration 42
WARNING
The keypad must be locked to ensure user safety.
Failure to follow this instruction may result in serious injury, e.g. due to
crushing by the door.
Copyright
Dexxo Smart 800 io / Dexxo Smart 1000 io
MY button
Down button
Stop
Complete closing
If door closed or
Complete closing
open: partial
opening
If door moving:
stop
Aux. output OFF
OFF
©