Dexxo Pro io
- beeps twice, the button is programmed for partial opening,
- beeps 3 times, the button is programmed for full opening.
10 - SPECIAL OPERATION
If there is a power outage while the door is being opened, when the power is
restored the door should return to its opening stop; if the door does not reach
its opening stop, it cannot be closed.
For other specific operations, see the user manual.
11 - CLEARING REMOTE CONTROLS AND
ALL SETTINGS
11.1 Clearing remote controls - Fig. 48 to 50
> Clearing Keytis or Keygo remote controls
Individually clearing a remote control button
This can be done:
- by programming from the Dexxo Pro motor (Fig. 20).
Programming a previously programmed button automatically clears any
previously stored programming settings.
- by directly clearing the remote control (only for Keytis remote controls)
(Fig. 48).
Simultaneously press the "PROG" button and the BUTTON to be cleared on
the remote control.
> Clearing all remote controls (Fig. 49)
[1]. Press the "PROG" button on Dexxo Pro until the light blinks (seven
seconds). This will:
- Clear the system key memorised by Dexxo Pro,
- Clear the programming for all memorised remote controls.
[2]. For Keytis remote controls, repeat the direct clearing procedure for all of
the Keytis remote control buttons programmed on the Dexxo Pro system:
Fig. 48.
> Keytis remote control general reset (Fig. 50)
Simultaneously press the "PROG" and "KEY" buttons. This will:
- perform a program general clear action (all buttons),
- clear all settings from the remote control (refer to Keytis io remote control
documentation),
- change the system key memorised by the remote control.
11.2 Resetting all settings - Fig. 51
Press the "SET" button until the light goes out (7 s).
This clears all previously stored settings and returns them to their default
values.
12 - LOCKING PROGRAMMING - FIG. 52
The keypad must be locked to ensure the safety of the end-users.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Pressing the "SET", "+", "-" buttons :
- start by pressing "SET".
- the "+" and "-" buttons must be pressed simultaneously within 2 seconds.
To access programming mode once again, repeat the same procedure.
13 - REFITTING COVERS
Refit the motor head and built in light covers (Fig. 53).
14 - TROUBLESHOOTING
14.1 Operating codes displayed
11
WARNING
Code
Description
Waiting for a command
Door opening
Waiting for the door to close
Door closing
Obstacle detection
Safety input active
Pedestrian door safety
contact active
Safety mechanism self test
Working from back-up battery
Waiting for a command
14.2 Programming codes displayed
Code
Description
Comments
Awaiting setting
Pressing the "SET" button for 2 s starts the
learning mode.
Learning mode
Pressing the "OK" button starts the learning
cycle: the S2 display blinks during the entire
cycle.
Pressing the "+" or "-" buttons will control the
motor in forced mode.
Awaiting motor
Pressing a remote control button will assign
control memorisation
this button to motor control.
Add a remote
Displayed during remote control
control
programming. (One-way controls).
Delete a remote
Displayed during remote control deletion.
control
(One-way controls)
One-way control
Displayed on reaching the maximum number
memory full
of channels that can be saved.
One-way control
Displayed when all the one-way remote
memory empty
controls have been deleted.
14.3 Error and failure codes displayed
Code
Description Comments
Maximum
During learning,
force reached
the door requires
too much force for
the motor.
Safety
The safety device
mechanism
self test failed
self test fault
Other faults
These codes
and failure
correspond to
conditions
various electronic
circuit board
failures.
For any other error or failure code, please contact Somfy
14.4 Accessing stored data
To access stored data, select the "Ud" setting then press "OK" as shown in
(Fig. 54).
Copyright © 2015 SOMFY ACTIVITES SA. All rights reserved
Comments
Displayed during obstacle
detection then for 30 s.
Displayed after a movement
request or during movement, when
the safety input is active.
This display is maintained as long
as the safety input is active.
Displayed after a movement
request or during movement, when
the pedestrian door contact is
open.
The display is maintained as long
as the pedestrian door contact
remains open.
Displayed during safety
mechanism self tests.
Action required?
Check door balance and
correct operation by manual
operation.
Check that "P2" is setup
correctly depending on the
devices connected to the safety
input.
Check safety device wiring.
When photoelectric cells
are used, check their proper
alignment.
Cut the power supply (mains &
battery back-up), wait for a few
minutes then re-connect the
power supply.
If the fault persists, contact
Somfy Technical Support.