Keep the
set values.
After completing the wheel data update, press the
unbalance values recalculated according to the new dimensions, or to perform a wheel spin.
- if two subsequent measurements are taken inside the rim on two balancing planes, the
machine interprets the presence of a rim with balancing using a clip weight on the inner
plane and an adhesive weight on the external one (ALU 2P).
In this phase, the machine could automatically change the type of weight on the inner
plane from clip to adhesive (ALU 1P). The operator is able to change this setting by press-
ing the
or
1P to ALU 2P and vice versa.
For models with automatic inner (distance and diameter) sensor
and automatic and outer mechanical (width) measuring sensors
To enter the distance,
diameter and width
values automatically,
proceed as follows:
- bring the automatic
internal measuring
arm (A, Fig. 8) into
contact with the in-
ner side of the rim as
shown in Fig. 12a and
at the same time bring
the automatic external
measuring arm (B, Fig. 8) into contact with the outer side Fig. 12a.
- Take great care to position the arm correctly so as to ensure accurate data reading.
- Keep the arms in contact with the rim until the machine has acquired the values. The
geometric data are displayed in sequence:
-A-
distance value;
-d-
diameter value;
-b-
width value.
When a geometric value is displayed, the corresponding LED illuminates on the display
panel.
Service Pro 750 Operator's manual
keys pressed to rapidly increase or decrease the previously
key. In this case, the balancing programme switches from ALU
button to exit and display the
UK
12a
97