• CAL on the left display
• -A- or diS on the right display
• Bring the lever of the internal feeler to
rest against the template as shown in
figure 26;
• Press the button
distance sensor calibration.
4. the machine will display the message:
• CAL on the left display
• -b- or LAr on the right display
• Return the internal probe to rest.
• Bring the arm of the automatic width
detector into contact with the template
as shown in figure 28.
- Press the enter key
the position of the detector;
- Return the arm to the rest position.
Notes:
If the calibration has been carried out
successfully, a confirmation message will
be displayed.
If the A20 message is displayed, the sen-
sor position in the calibration phase is not
correct. Position it correctly, as already
described, and repeat the procedure.
- Pressing the key
to interrupt the programme at any time.
128
to perform
to confirm
, it is possible
Operator's manual Service Pro 750
27
27a
28