• use the
for GAU CAL
• press the
bration, proceeding as follows:
1. The machine will display the following
message:
•
CAL on the left display
•
-0- on the right display
• Bring the automatic probe to the rest
position (fully inside) as shown in figure
24.
• press the key
calibration in the zero position.
2. the machine will display the message:
•
CAL on the left display
•
-d- or diA in the right display
• Bring the lever of the internal feeler to
rest against the template as shown in
figure 25;
• Press the button
the diameter sensor.
3. the machine will display the message:
•
CAL on the left display
•
-A- or diS on the right display
• Bring the lever of the internal feeler to
rest against the template as shown in
figure 26;
• Press the key
distance sensor.
• Return the internal probe to rest.
It is possible to exit the probe calibration
program by pressing the key
If the calibration has been carried out
successfully, an acoustic signal of consent
is emitted. The display of message A 20
instead indicates that the position of the
126
keys to search
key to perform cali-
to carry out the
to calibrate
to calibrate the
.
Operator's manual Service Pro 750
23
24
25