W
IRING DIAGRAM
: Wire clamp
: Terminal strip
: Connector
: Relay connector
: Field wiring
This wiring diagram only applies to the outdoor unit
NOTE 1
NOTE 4
Refer to the option manual for connecting wiring to X6A/X77A
Refer to the wiring diagram sticker (on back of front panel) on how to use BS1~BS4 and DS1 switch
NOTE 5
Do not operate the unit by short-circuiting protection device S1PH
NOTE 6
Confirm the method of setting the selector switches (DS1) by service manual. Factory setting of all switches: 'OFF'
NOTE 8
A1P~A4P................... Printed circuit board
BS1~BS4................... Push button switch
C1~C4 ....................... Capacitor
DS1 ........................... DIP switch
E1H ........................... Bottom plate heater
E1HC......................... Crankcase heater
F1U~F7U................... Fuse
HAP (A1P)................. Service monitor (green)
HAP (A2P)................. Service monitor (green) (for W1 model only)
H1P~H7P (A1P) ........ Service monitor (orange) (for W1 model only)
H1P~H7P (A2P) ........ Service monitor (orange)
K1M, K2M ................. Magnetic contactor (for W1 model only)
K1R~K4R .................. Magnetic relay
K10R, K11R .............. Magnetic relay (for V3 model only)
L1R~L4R ................... Reactor
M1C........................... Motor (compressor)
M1F ........................... Motor (fan) (upper)
M2F ........................... Motor (fan) (lower)
PS ............................. Switching power supply
Q1DI.......................... Earth leakage circuit breaker (field supply)
R1~R4 ....................... Resistor
R1T ........................... Thermistor (air)
R2T ........................... Thermistor (discharge)
Installation manual
13
BLK
: Black
GRN
: Green
BRN
: Brown
BLU
: Blue
ORG
: Orange
R3T............................ Thermistor (suction pipe)
R4T............................ Thermistor (heat exchanger)
R5T............................ Thermistor (heat exchanger middle)
R6T............................ Thermistor (liquid)
R7T............................ Thermistor (fin) (for W1 model only)
R10T.......................... Thermistor (fin) (for V3 model only)
RC ............................. Signal receiver circuit
S1NPH....................... Pressure sensor (high)
S1PH ......................... Pressure switch (high)
TC.............................. Signal transmission circuit (for V3 model only)
V1R............................ Power module (for V3 model only)
V1R, V2R................... Power module (for W1 model only)
V2R, V3R................... Diode module (for V3 model only)
V3R............................ Diode module (for W1 model only)
V1T ............................ Insulated gate bipolar transistor (for V3 model
X1M ........................... Terminal strip
X6A............................ Connector (option)
Y1E............................ Expansion valve
Y1S............................ Solenoid valve (4 way valve)
Y3S............................ Solenoid valve (for W1 model only)
Z1C~Z9C ................... Noise filter
Z1F~Z4F.................... Noise filter
RED
: Red
WHT
: White
YLW
: Yellow
only)
RRHQ0011~016AAV3(8) + RRHQ011~016AAW18
Outdoor unit for air to water heat pump
4PW50202-1