Displayed service
Err | PE
codes
(continued)
Cause:
Remedy:
Err | IP
Cause:
Remedy:
Err | bPS
Cause:
Remedy:
dSP | Axx, dSP | Cxx, dSP | Exx, dSP | Sy, dSP | nSy
Cause:
Remedy:
r
Cause:
Remedy:
r
Cause:
Remedy:
r
Cause:
Remedy:
no | Arc
Cause:
Remedy:
no | H2O
Cause:
Remedy:
hot | H2O
Cause:
Remedy:
The earth fault-current watchdog has triggered the safety cut-out of the
power source.
Switch off the power source, wait for 10 seconds and then switch it on
again. If you have tried this several times and the error keeps on
occurring - contact After-Sales Service.
Primary overcurrent
Contact After-Sales Service
Fault in power module
Contact After-Sales Service
Fault in central control and regulation unit
Contact After-Sales Service
| E30
r-Alignment: There is no contact with the workpiece.
Connect up the grounding (earthing) cable; ensure a tight connection
between the electrode and the workpiece
| E31
r-Alignment: Procedure has been interrupted by repeated pressing of the
torch trigger.
Ensure a tight connection between the electrode and the workpiece -
press the torch trigger once only.
| E33, r
| E34
r-Alignment: Poor contact between the tungsten electrode and the work-
piece
Clean the point of contact, check the grounding (earthing) connection
Arc-break
Press the torch trigger repeatedly; clean the surface of the workpiece
Cooling-unit flow watchdog has been triggered
Check the cooling unit; if necessary, top up the coolant and/or vent the
water forward-flow hose as described in "Putting the cooling unit into
service"
Thermostat on cooling unit has been tripped
Wait until the end of the cooling phase, i.e. until "Hot | H2O" is no longer
displayed. ROB 5000 or field-bus coupler for robot control: Before
resuming welding, initialise the "Source error reset" signal.