4-step

-
Important! The set-up parameter SFS must be set to "OFF" (see: "The Set-up menu:
Level 2"). The factory setting (i.e. in which the power source is delivered) is: Parameter
SFS = "OFF".
-
-
-
-
Fig.13 4-step mode
Select 4-step mode (3)
Welding start-up with starting current I
Welding with main current I
Lowering to final current I
End of welding: Release the torch trigger
I
I
S
GPr
t
up
: Pull back and hold the torch trigger
S
: Release the torch trigger
1
: Pull back and hold the torch trigger
E
I
1
30
I
E
t
t
G-L
down
G-H