If the Mode key is pressed and held down for 2 seconds, the display's status mode
NOTE
will change from the speed indication to the load indication and vice versa (see
parameters 22 and 23).
No.
Function
Customer
24
defined
scaling
Multiplying factor on motor speed (rpm) to give customer defined units
No.
Function
Security
25
set up
Used to set up a user security code.
No.
Function
Fwd/Rev
26
key enable
OFF - Keypad Forward / Reverse key disabled
On - Keypad Forward / Reverse key enabled
No.
Function
Power up
27
keypad ref.
In keypad control, this parameter selects the value of the keypad reference on power-
up.
0
keypad reference is zero
LASt
keypad reference is last value selected before the drive was powered down.
PrS1
keypad reference is copied from preset speed 1.
In keypad control, to look at the keypad reference with the drive disabled, press the
and
keys together.
In terminal control, to look at the keypad reference, press either the
No.
Function
Parameter
28
transfer
Quickey
no
Do nothing
rEAd
When this is set and the user performs a drive reset by pressing the STOP/
RESET key while the drive is disabled (ih), tripped (tr) or on stand-by (rd), the
Quickey contents will be copied to the drive and parameter 28 reset to no.
These parameters are then saved automatically by the drive.
Prog
When this is set and the user performs a drive reset by pressing the STOP/
RESET key, the Quickey contents will be updated with the current drive
EEPROM memory parameter settings. Parameter 28 is also reset to no.
Auto
When this is set and the user performs a parameter save by pressing the
mode button after adjusting a parameter value, the drives current EEPROM
memory parameter settings are saved in the Quickey.
Any parameter values that have been changed via serial communications but not
NOTE
stored in the drives EEPROM memory will not be stored in the Quickey.
Commander SE User Guide
Issue Number 9
Type
Limitations
RW
U
Type
Limitations
RW
U, S
Type
Limitations
RW
Bit
Type
Limitations
RW
T
Type
Limitations
RW
T, R
www.controltechniques.com
Range
Units
0 - 99.99
Range
Units
0 - 9999
Range
Units
On, OFF
Range
Units
0, LASt,
PrS1
Range
Units
no, rEAD,
Prog, Auto, boot
Defaults
1.00
EUR
1.00
USA
Defaults
0
EUR
0
USA
Defaults
OFF
EUR
OFF
USA
Defaults
0
EUR
0
USA
or
key.
Defaults
no
EUR
no
USA
57