Control Techniques Commander SE Guide D'utilisation page 56

Masquer les pouces Voir aussi pour Commander SE:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

.
No.
Function
Enable
negative
17
preset
speeds
OFF - direction of rotation controlled by the Run Forward and Run Reverse terminals
On - Direction of rotation controlled by the preset speeds value
(use the Run Forward terminal).
When negative preset speeds are enabled, a negative value entered in parameters 11,
12, 13 and 14 causes the motor to rotate in the reverse direction. If not enabled, all
negative values are treated as zero.
No.
Function
Last
18
trip
Defines the last fault trip of the drive.
No.
Function
Trip before
19
P18
Defines the second to last trip of the drive.
No.
Function
Trip before
20
P19
Defines the third to last trip of the drive.
No.
Function
Trip before
21
P20
Defines the fourth to last trip of the drive
No.
Function
Load
22
display
units
Ld - Active current as a % of motor rated active current
A - Drive output current per phase in A
No.
Function
Speed
23
display
units
Fr - Drive output frequency in Hz
SP - Motor speed in rpm
Cd - Machine speed in customer defined units
Cd (parameter 23) = Speed (rpm) x parameter 24
When parameter 23 is set to SP, the display will show a maximum of 9999 rpm. The
NOTE
Customer defined scaling (parameter 24) will only scale this maximum value not
on any higher values.
56
Type
Limitations
RW
Bit
Type
Limitations
RO
T, S
Type
Limitations
T, S
RO
Type
Limitations
T, S
RO
Type
Limitations
T, S
RO
Type
Limitations
RW
T
Type
Limitations
RW
T
www.controltechniques.com
Range
Units
On, OFF
Range
Units
Range
Units
Range
Units
Range
Units
Range
Units
Ld, A
Range
Units
Fr, SP, Cd
Commander SE User Guide
Defaults
OFF
EUR
OFF
USA
Defaults
-
EUR
-
USA
Defaults
-
EUR
-
USA
Defaults
-
EUR
-
USA
Defaults
-
EUR
-
USA
Defaults
Ld
EUR
Ld
USA
Defaults
Fr
EUR
Fr
USA
Issue Number 9

Publicité

Table des Matières
loading

Table des Matières