Used to start the drive.
Used to stop the drive. Also used to reset the drive after a trip.
After a reset command, the drive will need a start command to run.
Used to reverse the direction of rotation of the motor
(when parameter 26 = On).
No.
Function
Motor
06
rated
current
Enter the motor current rating (taken from the motor name plate).
The drive rated current value is the 100% RMS output current value of the drive. This
value can set to a lower value but not a higher value.
No.
Function
Motor
07
rated
speed
Enter the rated full load speed of the motor (taken from the motor name plate).
The rated speed is used to calculate the correct slip for the motor.
The rated speed is the synchronous speed - the 100% full load slip of the motor.
Example: For a 4 pole motor with a synchronous speed of 1500rpm and a slip speed of
70rpm, enter 1430rpm in parameter 07.
A value of zero entered into parameter 07 means slip compensation is disabled.
NOTE
If the full load speed of the motor is above 9999rpm, enter a value of 0 in parameter
NOTE
07. This will disable slip compensation as values greater than 9999 cannot be
entered into this parameter.
Slip compensation should be disabled when using Commander SE on a high
NOTE
inertia load, e.g. fan.
No.
Function
Motor
08
rated
voltage
Enter the motor rated voltage (taken from the motor name plate).
No.
Function
Motor power
09
factor
The motor power factor cos ϕ (taken from the motor name plate).
No.
Function
Parameter
10
access
L1 - Level 1 access - Only parameters 1 to 10 can be selected for viewing or adjusting.
L2 - Level 2 access - All parameters 1 to 54 can be selected for viewing or adjusting.
Loc - Used to lock a security code in the drive. See section 6.5 Security codes on
page 48.
54
Type
Limitations
RW
U
Type
Limitations
RW
U
Type
Limitations
RW
U
Type
Limitations
RW
U
Type
Limitations
RW
T
www.controltechniques.com
Range
Units
0 - Drive rated
A
current
Range
Units
0 - 9999
rpm
Range
Units
0 - 240
V
0 - 480
Range
Units
0 - 1.00
Range
Units
L1, L2, Loc
Commander SE User Guide
Defaults
Drive rating
EUR
Drive rating
USA
Defaults
1500
EUR
1800
USA
Defaults
230/400
EUR
230/460
USA
Defaults
0.85
EUR
0.85
USA
Defaults
L1
EUR
L1
USA