Setting the relative position of the arc/laser
Safety
Work that is carried out incorrectly can cause serious injury and damage.
Set up work must only be performed by trained and qualified personnel. Observe the safety
regulations in the operating instructions, paying particular attention to the section entitled
"Safety inspection".
Stick out
Fixing screws
NOTE!
The figure shows the LaserHybrid head without the housing cover.
Before starting up the LaserHybrid head, always fit the housing cover.
WARNING!
(1)
14 mm
(2)
NOTE!
When setting the physical position of
the welding torch, ensure the stick-out
is always 14 mm.
(1)
Welding torch
(3)
(2)
Contact tip
(3)
Stick out
73