Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualified person to
avoid dangers.
11. Transport
• Transport the electric tool by lifting it on the recesses
provided for this on the frame and the motor cover.
• Never use the protective devices for handling or
transport.
• Make sure that the exposed part of the saw blade
is covered during transport, e.g. by the protective
device.
12. Cleaning, maintenance and
ordering spare parts
m WARNING
Always switch the machine off and remove the mains
plug prior to all maintenance and cleaning work.
12.1 Cleaning
Keep protective devices, air vents and the motor hous-
ing as free of dust and dirt as possible. We recommend
cleaning the device directly after every use.
12.1.1 Exterior cleaning
• Clean the device at regular intervals using a damp
cloth and a little soft soap.
• Do not use cleaning agents or solvents. These could
damage the plastic parts of the device.
• Make sure that no water can penetrate the device
interior.
,QW H U L R U F O H D QLQJ¿ J
1.
Open the storage box (9).
2.
Remove the screw (34).
3.
Loosen the screw (33).
4.
Remove the cover (8).
5.
Blow out the device interior with low-pressure
compressed air.
6.
Attach the cover again (8).
7.
Fasten the screw (33).
8.
Insert the screw (34) again and tighten it.
9.
Close the storage box (9).
0DLQ W H Q DQ F H
% H D U L QJV¿ J LW H P
Lubricate the bearing points (10) of the deflection roll-
ers after approx. 25-30 operating hours at the latest
using high-quality machine grease.
12.2.2 Carbon brushes
If excessive sparks are generated, have an electrician
check the carbon brushes.
ATTENTION
The carbon brushes must only be replaced by an elec-
trician.
0DLQVF D EOH
If the mains cable is pulled out, cut, or damaged in
some other form, then it should be replaced immedi-
ately.
12.2.4 Replacing the fine-wire fuse (Fig. 16)
If the fine-wire fuse (7) is defective, it must be replaced
with a fine-wire fuse of the same type 5 A/250 V
(ø 5 x 20 mm).
m WARNING
Do not bypass the fine-wire fuse (7)! Do not use fus-
es of any other type! This can lead to damage to the
device.
12.3 Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consuma-
bles.
Wearing parts*: Carbon brushes, saw blade, table inlay
* may not be included in the scope of supply!
12.4 Ordering spare parts
Please provide the following information when ordering
spare parts (via the service hotline):
• Device type
• Device article number (can be found on the packag-
ing or in the instructions)
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
www.scheppach.com