15. Troubleshooting
m WARNING
Always switch the machine off and remove the mains plug prior to all maintenance and cleaning work.
Fault
Saw blade without pins
loosens after switching
off the engine
Motor does not start
Saw blades brake
Saw blade oscillates, not
aligned straightly.
Possible cause
Saw blade clamping screw (27/28) not
tightened enough
Mains fuse blown
Extension cable defective
Fine-wire fuse defective
Connection to the motor or switch not OK
Motor or switch faulty
Tension set incorrectly
Load too high
Incorrect saw blade type
Workpiece not fed straightly
Holders not aligned
www.scheppach.com
Remedy
Tighten the saw blade clamping screw
(27/28)
Check mains fuse
Replace the extension lead
Check the fine-wire fuse and, if
necessary, replace it with a fine-wire
fuse of the same type.
Have this checked by an electrician
Have this checked by an electrician
Set correct tension
Feed workpiece more slowly
Use correct saw blades
Avoid lateral pressure
Open the screws that fasten the holders.
Bring the holders into the vertical posi-
tion and tighten the screws again.
GB | 37