9.4 Work lamp operation (fig. 4)
Press the on/off switch (20) to switch the work lamp
(19) on and off.
6SH H G U H J X O DW R U ¿ J
The speed regulator (17) allows you to set the stroke
rate according to the material to be cut. In case of
soft material, we recommend high stroke rates, while
strokes rates should be kept low for hard material.
Turn the speed regulator (17) clockwise to increase the
stroke rate. Turning counterclockwise lowers the stroke
rate.
0DNLQJLQVLGH F X W V
This scroll saw allows inside cuts in workpieces with-
out damaging the outside or the circumference of the
workpiece.
1.
Remove the saw blade (21) as described in 8.2.
2.
Drill a hole into the workpiece.
3.
Place the workpiece with the drilled hole over the
opening of the table inlay (25) on the saw table (6).
4.
Install the saw blade (21) (as described in 8.2)
through the drilled hole in the workpiece and set
the blade tension.
5.
After completing the inside cut, remove the saw
blade (21) from the blade holders (as described in
8.2).
6.
Remove the workpiece from the table.
9.7 Carrying out mitre cuts (fig. 14)
m WARNING
Be particularly careful when making mitre cuts. The
incline of the saw table supports slipping. There is a
danger of injury.
1.
To carry out mitre cuts, adjust the distance be-
tween the saw blade guard (5) mounted to the re-
taining device (23) and the work table accordingly.
2.
Swivel the table by loosening the knurled nut (14)
and tilting the saw table (6) into the desired po-
sition.
3.
Tighten the knurled nut (14).
34 | GB
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been improp-
erly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions.
Only use connection cables with the marking
H 05 VV-F.
The printing of the type designation on the connection
cable is mandatory.
AC motor
The mains voltage must be 220-240 V~.
Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
www.scheppach.com
.