Beretta POWER PLUS 50 M Notice Installateur page 70

Table des Matières

Publicité

ENGLISH
EN
Dismantling and cleaning the burner and
the exchanger
- Remove the front and top panel of the
boiler (see the operations described on
Removing the front panel, accessing the
control panel and the inside of the boiler
p. 68).
- Remove the wiring (5) from the fan (6)
- Unscrew the two screws (8) that fasten the
fan (6) to the air conveyor (9)
- Unscrew the four screws (10) that fasten
the fan assembly (6) to the exchanger,
using a 10 mm socket wrench
- Remove the gasket (11) and remove the
burner (12)
- Remove the electrode plate (13), check
the condition of the electrode and replace
if necessary.
Once the cleaning operations have been
completed, reassemble the components in
the reverse order.
b
Check that the gas connection is tight.
70
FRANÇAIS
Démontage et nettoyage du brûleur et de
l'échangeur
- Enlever les panneaux avant et supérieur
de la chaudière (voir les passages décrits
Enlèvement du panneau avant, accès au
tableau de commande et aux parties inter-
nes de la chaudière p. 68).
- Débrancher le câblage (5) du ventilateur
(6).
- Dévisser les deux vis (8) qui fixent le venti-
lateur (6) au convoyeur de l'air (9).
- Avec une clé à tube de 10 mm, dévisser
les quatre vis (10) qui fixent le groupe ven-
tilateur (6) à l'échangeur.
- Enlever le joint (11) et sortir le brûleur (12)
- Démonter la platine porte-électrode (13),
vérifier l'état de l'électrode et, le cas
échéant, la remplacer.
Une fois les opérations de nettoyage ter-
minées, remonter les composants en
procédant à l'inverse de ce qui a été décrit.
b
Vérifier que le raccordement gaz est
étanche.
FR

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Power plus 50 m depPower plus 100 mPower plus 100 m depPower plus 100 sPower plus 100 s dep

Table des Matières