Fall Clearance; Cleaning, Maintenance And Storage - MSA V-EDGE CNB/P/11.060 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
Anchor locations shall adhere to Table 5, including a redirection angle 90º and set back 350 mm (1.1 ft); ensuring
the correct function of the device in the event of a fall. Lateral movements to both sides of the centre axis shall be
limited to a maximum of 1.5 m (5 ft) as shown. The V-EDGE PFL anchorage point shall be at the User's foot level or
above. Climbing above the anchorage point is not permitted. (See Table 5) Measures shall be taken to prevent use
over unintended edges (such as on the opposite side of the anchorage or around corners).
If a fall over an edge is possible, special rescue measures shall be de ned and trained. Consideration shall be given
to accessing a suspended user without further loading or moving the lifeline over an edge.

5 Fall clearance

Ensure suf cient clearance exists to prevent striking an obstacle or structure during a fall. Insuf cient clearance or
obstructions can prevent the function of the V-EDGE PFL.
Consult Table 4 (Vertical and horizontal use) or Table 5 (Horizontal use with edge consideration) for acceptable anchor locations
in relation to the User and for minimum clearance requirements. Fall clearance is calculated as the vertical distance between the
working platform and the rst obstacle below (such as the next platform or ground).
The clearance requirements indicated on the graph in Table 4 are based on freefall conditions. The presence of
obstructions (such as structure edges) may reduce clearance requirements, but may introduce additional hazards, such as
potential for laceration or impact injuries. Additional clearances may be required to account for the effects of a swing fall.
Only attach the V-EDGE PFL to an anchor that may de ect or deploy in a fall, such as a deadweight anchor or anchor
line, where there is no risk of the line contacting an edge. In such cases, the additional deployment of the anchor shall
be added to the minimum clearances speci ed in Table 4 (non-edge).
To reduce the potential for injury in a fall, the fall distance should be minimised.

6 Cleaning, maintenance and storage

If required, the V-EDGE PFL exterior and lifeline may be cleaned using a damp cloth and warm water (max. 40°C),
and allowed to dry naturally before use. Excessive build-up of dirt, paint etc. may compromise both retraction and
strength of the lifeline.
Store or transport the V-EDGE PFL in a cool, dry, clean environment, away from dust, oil and direct sunlight. During
transportation, the device shall be protected to prevent damage or contamination. Examine the V-EDGE PFL after
long periods of storage prior to returning it to service.
When not in use, store with the lifeline fully retracted as prolonged periods of full extraction may weaken the retraction
spring. If the lifeline is released, it will retract at high speed, potentially damaging internal parts and / or causing kinks
in the lifeline.
Moving parts of snaphooks, carabiners, and the attachment bracket may require periodic lubrication with low viscosity
penetrating oil. Follow lubricant manufacturer's instructions. Do not over-lubricate. Wipe excess with a clean, dry cloth.
7 Pre-use checks and periodic examination (Table 2)
The safety of the User relies upon the continued ef ciency and durability of the equipment, therefore pre-use checks shall
be completed before each use. Periodic examinations shall be completed by a person, other than the User, competent
in the examination of V-EDGE PFLs, in accordance with MSA instructions for periodic examination. The interval will be
dictated by the usage (Table 7), local regulations or environmental conditions, and shall be at least annually.
Records shall be kept of the results of the examination. An example periodic examination log can be downloaded from this
product's page on MSAsafety.com by clicking on the Literature tab.
Table 7
Periodic examination interval
Usage
Infrequent to light
Moderate to heavy
Severe to continuous
Usage shall be determined by a competent person.
The V-EDGE PFL is not repairable. The V-EDGE PFL shall not be altered or added to. If the V-EDGE PFL has been
subjected to a fall, is unable to pass inspection, an issue has been identi ed, or any doubt exists as to the suitability of
the V-EDGE PFL it shall be tagged "UNUSABLE" and disposed of in accordance with local regulations.
Maximum product life:
Continued use is dependent upon passing pre-use checks and periodic examinations. Service life may be reduced by
frequency and conditions of use or local regulations.
1.Competent person: a person, other than the User, competent in the examination of PPE in accordance with MSA instructions.
Interval
Annually (12 months)
Semi-annually to annually (6-12 months)
Quarterly to semi-annually (3-6 months)
1