6. CONNECTING PERIPHERALS

Warning
The connection operations must be performed with the power off.

6.1. General wiring diagram - Fig. 16

Terminals
Connection
1
L
230 V power supply
2
N
3
Aux
Area lighting
4
Dry contact
5
Flash
24 V - 15 W orange
light output
6
7
-
24 V accessories
power supply
8
+
9
Tx
Power supply for pho-
toelectric cell trans-
mitter for auto-test
10
Batt
Battery
11
12
TOTAL control input
13
Common
14
PEDESTRIAN control
input
15
Test
Safety test output
16
Se
Safety edge safety
input
17
Common
18
Cell
Cell safety input
19
Ant
Antenna earth
20
Antenna core

6.2. Description of the various peripherals

6.2.1. Photoelectric cells - Fig. 17
Carry out the following operations:
NB
The order of these operations must be complied with.
1) Remove the bridge between terminals 17 and 18.
2) Connect the cells
Fig. 17A - without auto-test
Fig. 17B - BUS
Fig. 17C - with auto-test
Allows an automatic test to be carried out to check the operation of the
photoelectric cells each time the door moves.
3) Program parameter P4.
without auto-test: "P4" = 1
BUS: "P4" = 2
with auto-test: "P4" = 3
Warning
It is compulsory to install photoelectric cells WITH AUTO-TEST P4
= 3 if:
• remote control of the mechanism is used when the door is not
visible,
• automatic closing is activated ("P0" = 2 or 3).
4) In the case of BUS cells, perform drive auto-programming again.
7
Comments
Earth connection available
on the motor flange
Max. 230 V - 500 W
• either 5 fluocompact or
LED lights
• or 2 power supplies for
low-voltage LEDs
• or 1 halogen light, max.
500 W
Compatible with 9.6 V
battery
NO dry contact
NO dry contact
NC dry contact
NC or BUS dry contact
6.2.2. Reflex photoelectric cell - Fig. 18
Program parameter "P4" = 1.
6.2.3. Orange light - Fig. 19
6.2.4. Videophone - Fig. 20
6.2.5. Antenna - Fig. 21
Connect the antenna cable to terminals 20 (core) and 19 (braid).
6.2.6. Safety edge - Fig. 22
NB
The auto-test is mandatory for the connection of any active safety
edge to ensure that the installation is compliant with the standards
in force.
Safety edge active with auto-test, ref. 9019611: program parameter
"Px" = 2.
Allows an automatic test to be carried out to check the operation of the
safety edge each time the gate moves.
6.2.7. 9.6 V battery - Fig. 23
Degraded operation: speed reduced and constant (no slowing at end limit),
24 V accessories inactive (including cells).
Battery life: 3 cycles/24 hrs
6.2.8. Area lighting - Fig. 24
For class I lighting, connect the earth wire to the earth terminal on the
base.
NB
The earth wire must always be longer than the live and neutral
wires in case of detachment.
The lighting output must be protected by a 5 A time-delay fuse (not
supplied).
Lighting output power:
• either 5 fluocompact or LED lights
• or 2 power supplies for low-voltage LEDs
• or 1 halogen light, max. 500 W

7. ADVANCED PARAMETER SETTING

7.1. Using the programming interface - Fig. 25

1) Press the "SET" button to enter parameter setting mode.
Indicator light P0 flashes once.
2) Press the "+" or "-" button to change the value of the parameter.
The indicator light flashes x times to indicate the value selected.
3) Press the "SET" button to confirm this value and move on to the next
parameter.
4) Press the "SET" button for 2 s to confirm a value and exit parameter
setting mode.
The parameter setting indicator lights are out.
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.