9. ParamEtEr sEttiNG

During the setting operations, the motor must be off.
When modifying the settings, it is necessary to switch the control unit off and on again to activate these new
settings.

9.1. setting the operating modes

The operation parameters are set using micro switches
SW1 and SW2.
operation
operating mode of
photoelectric cells
activate/deactivate
the automatic
closing function with
movement in front of
the cells
impact against an
obstacle
activating/deactivating
orange light warning
method of operation
do Not usE
14
setting
description of operation
Photoelectric cell input active only for closing: if the cells are obstructed in
the closing phase, the gate will stop and then reopen. If they are obstructed when
opening, the gate will continue to open.
Photoelectric cell input active when opening and closing: if the cells are
obstructed when opening, the gate will stop and start again when the cells are no
longer obstructed. if the cells are obstructed in the closing phase, the gate will stop
and then reopen.
automatic closing function deactivated.
automatic closing function activated: moving in front of the cells causes the gate
to close immediately.
obstacle detection activated: Impact against an obstacle, in both opening and
closing phases, is detected by an encoder system which blocks the gate and
reverses movement by 10 cm -see page 5-
obstacle detection deactivated: Impact against an obstacle is not detected and the
motor continues driving.
If obstacle detection is deactivated, use other safety systems (e.g.:
safety edge) in accord with the standards in force.
It is the installer's responsibility to ensure that the automatic installation
and its operation are compliant with the standards in force.
Warning deactivated: the orange light comes on when the gate opens.
Warning activated: the orange light comes on 3 seconds before the gate opens.
sequential mode: 4 steps
During opening: sending an open/close command stops motion, a successive
command causes the gate to close.
During closure: sending an open/close command stops motion, a successive
command causes the gate to open.
During the gate open pause: an open/close command cancels the pause time and
causes the gate to close immediately.
semiautomatic mode: 3 steps
During opening: if an open/close command is sent, it is ignored and the gate
continues to open.
During closure: sending an open/close command blocks the gate for a few seconds
and then it opens again.
During the gate open pause: an open/close command cancels the pause time and
causes the gate to close immediately.
leave in off position.
PAUSA
PAUSA
LAVOR
LAVOR
A A
O
O
PROG
PROG
20
20
19
19
START
START
18
18
PED
PED
STOP
STOP
FOTO
FOTO
FCA
FCA
DL10
DL10
FCC
FCC
COSTA
COSTA
10
10
9
9
DL11
DL11
8
8
7
7
6
6
5
5
4
4
3
3
F1
F1
2
2
1
1
Copyright © 2011 Somfy SAS. All rights reserved.
DL12
DL12
PROG
PROG
F2
F2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elixo 1300Elixo 2000

Table des Matières