Advanced Parameter Setting; Using The Programming Interface; Meaning Of The Different Parameters - SOMFY Dexxo Smart 800 io Manuel D'installation

Masquer les pouces Voir aussi pour Dexxo Smart 800 io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dexxo Smart 800 io / Dexxo Smart 1000 io
Reflex photocell
> > > Illustration 26
1] Remove the bridge between terminals 17 and 18.
2] Wire the cells.
3] Program P4=1.
See also
2 Meaning of the different parameters [} p.21]
6.2.2
Orange light
> > > Illustration 27
6.2.3
Video door phone
> > > Illustration 28
6.2.4
Antenna
> > > Illustration 29
Connect the antenna cable to terminals 19 (braid) and 20 (core).
6.2.5
Gate contact
> > > Illustration 30
6.2.6
9.6 V battery
> > > Illustration 31
Degraded operation: speed reduced and constant (no slowing at end limit),
24 V accessories inactive (including cells).
Battery life: 3 cycles/24 hrs
6.2.7
Area lighting
> > > Illustration 32
For class I lighting, connect the earth wire to the earth terminal on the base.
CAUTION
The earth wire must always be longer than the live and neutral wires in case
of detachment.
The lighting output must be protected by a 5 A time-delay fuse (not sup-
plied).
Lighting output power:
• either 5 fluocompact or LED lights
• or 2 power supplies for low-voltage LEDs
• or 1 halogen light, max. 500 W
7

ADVANCED PARAMETER SETTING

7.1

Using the programming interface

> > > Illustration 33
1] Press the "SET" button for 0.5 s to enter parameter setting mode.
ð The integrated lighting comes on and the P0 indicator light flashes
once.
2] Press the "+" or "-" button to change the value of the parameter.
ð The indicator light flashes x times to indicate the value selected.
3] Press the "SET" button for 0.5 s to confirm this value and move on to
the next parameter.
ð If parameter Px is selected, press the "SET" button for 0.5 s to exit
parameter setting mode.
4] Press the "SET" button for 2 s to confirm a value and exit parameter
setting mode.
è The integrated lighting and parameter setting indicator lights go
out.
7.2

Meaning of the different parameters

(Text in bold = default values)
P0
Operating mode
Values
1: sequential
2: sequential + short closure time-delay (60 s)
3: sequential + long closure time-delay (120 s) + blockage of
cells (2 s)
©
Copyright
2021 SOMFY ACTIVITES SA. All rights reserved.
P0
Operating mode
Comments P0 = 1: Each press on the remote control causes the motor to
move (initial position: door closed) as per the following cycle:
open, stop, close, stop, open, etc.
P0=2: This operating mode is only authorised if photoelectric
cells are installed and P4 = 3.
In sequential mode with short closing time-delay:
• the door will close automatically after a time-delay of
60 s,
• pressing a button on the remote control interrupts the
movement taking place and the closure time delay (the
door remains open).
P0=3: This operating mode is only authorised if photoelectric
cells are installed and P4 = 3 .
In sequential mode with long closing time-delay + cells
locked:
• the door will close automatically after a time-delay of
120 s.
• pressing a button on the remote control interrupts the
movement taking place and the closure time delay (the
door remains open).
• after the door is opened, movement in front of the
cells (safe closure) will close the door after a short
timed delay (fixed at 2 s). If no movement occurs in
front of the cells, the door will close automatically
after a time-delay of 120 s. If there is an obstacle in the
cells' detection zone, the door will not close. It will
close once the obstacle is removed.
P1
Door closing speed
Values
1: Slow
2: Standard
3: High speed
Comments If the parameter has been changed, you are advised to
perform auto-programming again.
WARNING! If the parameter has been changed, the
installer must check that the obstacle detection system
complies with Annex A of standard EN 12 453. Failure to
follow this instruction may result in serious injury, for
example due to crushing by the door.
P2
Closing slowdown zone
Values
1: None
2: Short (approx. 20 cm)
3: Long
Comments If the parameter has been changed, you are advised to
perform auto-programming again.
WARNING! If the parameter has been changed, the
installer must check that the obstacle detection system
complies with Annex A of standard EN 12 453. Failure to
follow this instruction may result in serious injury, for
example due to crushing by the door.
P3
Obstacle detection sensitivity
Values
1: Very low
2: Low
3: Standard
4: Maximum
Comments If the parameter has been changed, you are advised to
perform auto-programming again.
WARNING! If the parameter has been changed, the
installer must check that the obstacle detection system
complies with Annex A of standard EN 12 453. Failure to
follow this instruction may result in serious injury, for
example due to crushing by the door.
P4
Photoelectric cells
Values
CAUTION! Before modifying parameter P4, it is essential
to wire the cells (see Photoelectric cells [} p.20])CAUTION!
1: Active for standard cells or reflex photocell without
auto-test
2: Active for 2-wire bus cells
3: Active for standard cells with auto-test via power supply
switching
4: Inactive
EN
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dexxo smart 1000 io

Table des Matières