advaNCEd ParamEtEr sEttiNG

Navigating the parameter list

Press ...
to...
Access and exit the parameter setting menu
Navigate the parameters and codes list:
. short press = normal scrolling through individual parameters
. press and hold = rapid scrolling through parameters
C onfirm:
. the parameter selection
. the parameter value
Increase/decrease the value of a parameter
. short press = normal scrolling through individual parameters
. press and hold = rapid scrolling through parameters

Parameter value display

If the display is fixed, the displayed value is the value selected for this parameter.
If the display is flashing, the displayed value is the value selectable for this parameter.
meaning of different parameters
Code
description
values (bold = default)
P01
Complete cycle
0: sequential
operating mode
1: sequential + timed close
2: semiautomatic
3: automatic
4: automatic + cell blocking
5: deadman's control (wire)
P02
Complete operating
0 to 30 ( value x 10 s = time delay
mode automatic timed
closing
2: 20 s
Copyright © 2012 Somfy SAS. All rights reserved
setting
completed
value)
Comments
Each press on the remote control causes the motor to move (initial position: gate
closed) as per the following cycle: open, stop, close, stop, open, etc.
Operation in
In sequential mode with automatic timed close:
automatic closing
- the gate closes automatically after the time delay programmed
mode is only
in parameter "P02",
authorised if the
- pressing a button on the remote control interrupts the
photoelectric cells
movement taking place and the timed close (the gate remains
are fitted.
open).
i.e. P07=1 to 4.
In semiautomatic mode:
- pressing a button on the remote control during opening has no effect,
- pressing a button on the remote control during closing causes it to reopen.
In automatic closure mode:
- the gate closes automatically after the time delay programmed
in parameter "P02",
- pressing a button on the remote control during opening has
no effect,
- pressing a button on the remote control during closing causes
it to reopen,
Operation in
- pressing a button on the remote control during the closing time
automatic closing
delay restarts the time delay (the gate will close when the new
mode is only
time delay has elapsed).
authorised if the
If there is an obstacle in the cells' detection zone, the gate will
photoelectric cells
not close. It will close once the obstacle is removed.
are fitted.
After the gate is opened, movement in front of the cells (safe
i.e. P07=1 to 4.
closure) will close the gate after a short time delay (fixed at 2
seconds).
If there is no movement in front of the cells, the gate will close
automatically after the timed close programmed in parameter
"P02".
If there is an obstacle in the cells' detection zone, the gate will
not close. It will close once the obstacle is removed.
In wired deadman mode*
- the gate can only be controlled by continuous action on a wired control,
- the radio controls are inactive.
If value 0 is selected, the gate immediately closes automatically.