9.3.3
Dismantling / Removal of the Centrifugal Pump
The pump must be allowed to reach room temperature.
Disconnect the power supply.
Close valves (on the suction and pressure sides).
Empty the pump via the drainage screw 11
Disconnect motor.
Remove existing additional connections.
Release pressure and suction nozzles.
Release pump from its base plate.
Lift pump completely off.
Important:
When emptying the centrifugal pump please observe the following instructions!
!
1. If the pump was used to deliver liquids that are hazardous to health, then
great care must be taken in emptying the pump that neither persons nor
the environment are placed at risk through the process.
2. If necessary, wear protective clothing and protective mask!
3. The rinsing liquid used and any residual fluid out of the pump must be
caught and disposed of properly and without placing persons or the
environment in any danger.
4. Pumps that deliver liquids that are hazardous to health must be
decontaminated. In draining the delivery medium off care must be taken
that neither persons nor the environment are placed in any danger.
5. Legal requirements must be adhered to!