4
3
5
1
2
The position of the 5-pin M12 fixed connector is adjustable:
→
Unscrew the locknut.
→
Turn the fixed connector to the desired position, by 360° max. to
prevent the cables from twisting inside the housing.
→
Tighten the locknut using a spanner, while keeping the fixed con-
nector in the desired position.
Fig. 27:
Pin assignment of the 5-pin M12 fixed connector
The current output can be connected in either sourcing or
sinking mode. See Fig. 30 and Fig. 31 for the related wiring
charts.
24
1: V+ (12-36 V DC)
2: Negative 4-20 mA output
3: 0 V DC
4: Positive 4-20 mA output
5: Functional earth
English
installation and wiring
Installationandwiring
7.3.7.
Wiring the version with relay and
current outputs (8-pin m12 fixed
connector)
Warning
shock hazard due to the voltage at the relay terminals, which
is higher than 48v.
• Before powering the device, always check that the connectors
are correctly plugged-in and tightened.
the device is not tight when the en 175301-803 fixed
connector is not wired:
→
Unscrew the nut [1] (see Fig. 10) on the 2508 female
connector supplied with the device.
→
Insert the plug with order code 444509, supplied with
the device, into the cable gland.
→
Screw the nut back.
→
Plug the sealed 2508 connector onto the
EN 175301-803 fixed connector.
1: Common
2: Relay, normally closed (NC)
1
2
2
1
3: Relay, normally open (NO)
3
3
4: Not connected
Fig. 28:
Pin assignment on the EN 175301-803 fixed connector