Maintenance and troubleshooting
reassembly
→
Identify the active rotor [41] by running a metal object over the
face (smooth side).
The neutral rotor [42] is the other one (without magnet).
→
Replace the active rotor [41]:
- nearest the dimple [10],
- smooth side in the body meter [6].
→
Replace the neutral rotor [42] at 90° to the active rotor [41]
(see Fig. 7).
→
Lightly rotate the rotors by hand; they must turn freely.
→
Install gasket [5].
→
Replace the cover [2].
→
Replace screws [1] and fasten in an alternating pattern with a
torque of 6,5 Nm.
Type 8077
9.5
replace the cover with electronic
module
The electronic module [9] includes a Hall effect sensor and a Reed
switch.
Disassembly
→
Turn the electronic module [9] counter-clockwise with an angle
of about 90° to unlock it.
→
Remove the electronic module [9].
reassembly
→
Place the electronic module [9] in the cam [7].
→
Turn the electronic module [9] clockwise with an angle of about
90° to lock it.
The electronic module is locked with the complete device.
English