Available Versions Of The Se32 Electronic Module - Burkert 8032 Manuel D'utilisation

Masquer les pouces Voir aussi pour 8032:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Description
frequency proportional to the flow rate (f = KxQ, f is the frequency in Hz, K the proportionality factor, called K factor, in pulse/litre, which is
specific to each S030 fitting, and Q is the flow rate in l/s).
• The device 8072 detects the rotation of the oval gears of the S070 fitting. The oval gears generate a measuring signal with a frequency
proportional to the flow rate. The proportionality factor, called K factor, is specific to each S070 fitting.
5.3.

Available versions of the se32 electronic module

The order codes of the S030 or S070 fittings can be taken from the related data sheet: refer to the data sheets to select the fitting suited to
your application.
supply
se32 version
voltage
Threshold
12-36 V DC
detector
Threshold
12-36 V DC
detector
Threshold
12-36 V DC
detector
Threshold
12-36 V DC
detector
Flowmeter
12-36 V DC
Flowmeter
12-36 V DC
Flowmeter
12-36 V DC
Description
output
Transistor, NPN
EN 175301-803 male fixed connector
Transistor, PNP
EN 175301-803 male fixed connector
Transistor, NPN
Male 5-pin M12 fixed connector
and PNP
Relay
Male 5-pin M12 and male EN 175301-803 fixed connectors
4-20 mA + Relay
Male 8-pin M12 and male EN 175301-803 fixed connectors
4-20 mA + Relay
Male 5-pin M12 and male EN 175301-803 fixed connectors
4-20 mA
Male 5-pin M12 fixed connector
electrical connection
English
ul
order code
no
436474
no
434871
no
436473
yes
553431
no
436475
no
560547
no
560402
no
560403
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

8072

Table des Matières