There must be a free, level area (2) with a
radius of at least 1 m in front of the docking
station (1). Remove any bumps or
depressions.
External docking station:
In the case of an external docking
station (1) the docking station is located
outside the mowing area (A).
In conjunction with an external
docking station, search loops must
be installed for offset drive home.
(
11.11)
96
Minimum clearance to the mowing area:
A = 0,5 m
Maximum clearance to the mowing area:
B = 12 m
There must be a free, level area beyond
the perimeter wire and to the side of the
docking station (1). Remove any bumps or
depressions.
Width of the free area: C = 0,4 m
Fastening the docking station:
Fix the docking station (B) into position at
the chosen location using four pegs (E).
The ground at the chosen location should
be horizontal. The docking station must
not be inclined by more than 2 cm
rearwards or 8 cm forwards. Never bend
the floor plate. Any unevenness must be
removed under the floor plate so that it
fully contacts the ground.