1  Getting Started
5. Install the sense plug and the sense connector cover.
Remote Sense Operation
Turn the sensing function on and off using the SENSE switch located below the LAN connector on the
rear panel. Make sure the output is off when flipping the sense switch.
Flipping the SENSE switch up (RMT) turns the remote sense function on. Flipping it down (LCL) turns
remote sensing off. The above figure shows the remote sense function turned off.
The following sense fault will allow the unit to continue to operate, but the output voltage will fluctuate
by several volts.
When the sense wires come loose (open) during operation
l
The following sense faults will trigger a sense fault protection (SF) on the front panel and disable the
output.
When the sense wiring is reversed at the load
l
When the sense wires are shorted together
l
When both sense wires are connected to the Line at the load
l
When both sense wires are connected to the Neutral at the load
l
When the voltage drop exceeds 1 Vrms for a single load wire
l
A local lockout (LLO) command sent via the remote interface disables the operation of the
sense switch. To enable the operation of the sense switch, Use a communication
command to clear the local lockout (LLO) command