3  SCPI Programming Reference
OUTPut Subsystem
The OUTPut subsystem configures the output state, power-on state, coupling mode, digital pin, and
protection.
OUTPut[:STATe] ON|1|OFF|0
OUTPut[:STATe]?
Enables or disables the instrument's output.
Parameter
Typical Return
ON|1|OFF|0
0 (OFF) or 1 (ON)
Turn on the output: OUTP ON
The
*RST
command sets this parameter to 0.
OUTPut:COUPling AC|DC|ACDC
OUTPut:COUPling?
Sets the output coupling mode.
Parameter
Typical Return
AC|DC|ACDC
AC, DC, or ACDC
Default AC
Set the output mode to ACDC: OUTP:COUP ACDC
AC (default) produces AC output
DC produces DC output
ACDC combines AC and DC output
The *RST command sets this parameter to AC.
146
Keysight AC6800B Series Operating and Service Guide

Publicité

loading

Ce manuel est également adapté pour:

Ac6801bAc6802bAc6803bAc6804b