3  SCPI Programming Reference
Command Quick Reference
ABORt Subsystem
Command/Query Description
ABORt[:ALL]
Aborts both TRANsient and ACQuire operations.
ABORt:ACQuire
Aborts all ACQuire operations.
ABORt:TRANsient
Aborts all TRANsient actions.
CALibrate Subsystem
Command/Query
CALibrate:COUNt?
CALibrate:CURRent:OFFSet <value>
CALibrate:DATA <value>
CALibrate:DATE "<date>"
CALibrate:DATE?
CALibrate:LEVel P1|P2|P3|P4|P5
CALibrate:PASSword "<password>"
CALibrate:SAVE
CALibrate:STATe ON|1|OFF|0 [,<pass-
word>]
CALibrate:STATe?
CALibrate:VOLTage[:LEVel] <value>
CALibrate:VOLTage:OFFset <value>
CURRent Subsytem
Command/Query
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <value>|MINim-
um|MAXimum
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
[SOURce:]CURRent:OFFSet[:IMMediate] <value>|MINimum|MAXimum
[SOURce:]CURRent:OFFSet[:IMMediate]? [MINimum|MAXimum]
[SOURce:]CURRent:PROTection:STATe ON|1|OFF|0
[SOURce:]CURRent:PROTection:STATe?
110
Description
Returns the calibration count.
Starts the DC current limit calibration for the specified voltage range.
Enters the calibration value read from a multimeter.
Sets the calibration date.
Advances to the next calibration point.
Sets the Admin password, which is used for calibration.
Saves the calibration data and date, not the administration password, into nonvolatile
memory.
Enables or disables calibration mode.
Selects the AC voltage range to calibrate.
Selects the DC voltage range to calibrate.
Keysight AC6800B Series Operating and Service Guide
Description
Sets the immediate AC current limit in amps
(rms).
Sets the immediate DC current limit in amps.
Enables or disables current protection.