3 SCPI Programming Reference
OUTPut:PROTection:CLEar
Resets the latched protection. This clears the latched protection status that disables the output when
a protection condition occurs. It also clears the latched Inhibit Input function.
Parameter
Typical Return
(none)
(none)
Clears the latched protection status: OUTP:PROT:CLE
All conditions that generate the fault must be removed before the latched status can be cleared. The
output remains in the OFF state after the fault/inhibit condition is cleared.
OUTPut:PROTection:WDOG[:STATe] ON|1|OFF|0
OUTPut:PROTection:WDOG[:STATe]?
Enables or disables the I/O watchdog timer.
Parameter
0|OFF|1|ON
Enables the watchdog timer protection: OUTP:PROT:WDOG ON
When the watchdog timer is enabled, the output will be disabled if there is no I/O activity on any
remote interface within the time period specified by OUTput:PROTection:WDOG:DELay. The output is
latched off but the programmed output state is not changed.
The watchdog timer function is NOT reset by front-panel activity; the output will still shut down after
the time period has elapsed.
The
*RST
command sets this parameter to 0.
OUTPut:PROTection:WDOG:DELay <value>|MINimum|MAXimum
OUTPut:PROTection:WDOG:DELay? [MINimum|MAXimum]
Sets the watchdog delay time.
Parameter
1 to 3600 (seconds)
Sets a watchdog delay for 600 seconds: OUTP:PROT:WDOG:DEL 600
Values (seconds) must be whole numbers.
The
*RST
command sets this parameter to 60.
148
Typical Return
0 (OFF) or 1 (ON)
Typical Return
+6.00000E+02
Keysight AC6800B Series Operating and Service Guide