Télécharger Imprimer la page

Keysight AC6800B Serie Guide D'utilisation Et D'entretien page 123

Publicité

Les langues disponibles

Les langues disponibles

CALibrate:PASSword "<password>"
Sets the Admin password, which is used for calibration.
Parameter
an alphanumeric string of 4 to 15 characters (none)
Set the password to 12345: CAL:PASS "12345"
The password must be 4 to 15 characters long and may include any of these characters:
Characters
Description
A-Z
Upper case letters
a-z
Lower case letters
0-9
Numeric digits
+ - ( ) . , <space> Plus, minus, parentheses, period, comma, space
The
CALibrate:STATe
must be ON to execute this command.
This command increments the calibration count by 1.
The password is case sensitive.
To change the password: unsecure calibration memory with the old code, then set the new code.
If you enter an empty string as the new password and save it with CAL:SAVE once, no password will be
required to newly enter the calibration mode the next time.
This setting is non-volatile; it will not be changed by power cycling or *RST.
CALibrate:SAVE
Saves the calibration data and date, not the administration password, into nonvolatile memory. Do this
at the end of the calibration to avoid losing changes.
Parameter
(none)
Store calibration constants into nonvolatile memory: CAL:SAVE
The
CALibrate:STATe
must be ON to execute this command.
This command increments the calibration count by 1.
Keysight AC6800B Series Operating and Service Guide
Typical Return
Typical Return
(none)
3  SCPI Programming Reference
123

Publicité

loading

Ce manuel est également adapté pour:

Ac6801bAc6802bAc6803bAc6804b