3  SCPI Programming Reference
[SOURce:]VOLTage:PROGramming:SOURce INTernal|EXTAC|EXTDC
[SOURce:]VOLTage:PROGramming:SOURce?
Sets the voltage programming source.
Parameter
Typical Return
INTernal|EXTAC|EXTDC
INT, EXTAC, or EXTDC
Set the voltage programming source to external AC:
VOLT:PROG:SOUR EXTAC
The EXTAC and EXTDC modes require the analog interface card.
The
*RST
command sets this parameter to INTernal.
[SOURce:]VOLTage:RANGe[:UPPer] 155|310|MINimum|MAXimum
[SOURce:]VOLTage:RANGe[:UPPer]? [MINimum|MAXimum]
Sets the voltage range. If the voltage range is switched, the
are cleared, and ABORt[:ALL] is applied.
Parameter
155|310|MINimum|MAXimum +2.70000E+02
Set the voltage range to 310 V
VOLT:RANG MAX
You may only set this parameter if output is OFF.
Setting this parameter turns voltage autoranging OFF and aborts both TRANsient and ACQuire
operations.
The
*RST
command sets this parameter to 155.
If you enter a value between 0 and 155, the 155 V range will be chosen. If you enter a value above 155
V, the 310 V range will be chosen.
[SOURce:]VOLTage:RANGe:AUTO ON|1|OFF|0
[SOURce:]VOLTage:RANGe:AUTO?
Enables or disables voltage autoranging. If this parameter changes, the
VOLT:OFFS:TRIG
settings are cleared, and all operations are aborted.
Parameter
Typical Return
ON|1|OFF|0
0 (OFF) or 1 (ON)
Turn on voltage autoranging:
VOLT:RANG:AUTO 1
The
*RST
command sets this parameter to OFF.
168
Typical Return
Keysight AC6800B Series Operating and Service Guide
VOLT:TRIG
and
VOLT:OFFS:TRIG
VOLT:TRIG
and
settings