Les langues disponibles

Operation
Fig. 97: Open engine cover
B
Fig. 99: Opening and closing the engine cover
Battery master switch
A
A
Fig. 100: Battery master switch
3-42
Opening the engine cover
Unlock and open the engine cover.
Let the engine cover engage in position A.
A
• It is locked by letting curved rail B engage in position A.
Close the engine cover
Unlock the engine cover.
• It is unlocked by raising curved rail B.
Lower the engine cover slowly.
Ensure that the engine cover closes correctly.
Close the engine cover.
Lock the engine cover.
From serial number WNCE0801VPAL01769, the vehicle has a battery isolator switch.
The battery isolator switch is located under the engine cover.
Interrupt the electric power supply:
Flip up the battery isolator switch A and remove from the B positive terminal.
Establish the electric power supply:
Set the battery isolator switch A to the positive terminal B and fold down.
B
WARNING
Warning!
Danger of accident from interrupted electric power supply in
the HPU operation!
Can cause serious injury or death.
• HPU operation with interrupted electric power supply is forbidden, as
safety-related functions (e.g. light, horn) do not work.
OM 803 us – Edition 3.7 * * 803b330.fm